Materials
Compare Materials
Compare candidate materials with unit-aware values and condition metadata.
| Property |
Aluminum 3003-H14 plate and sheet (QQ-A-250/2E)
Aluminum 3003-H14, historical QQ-A-250/2E minimums | plate and sheet
|
|---|---|
| Density |
Not listed
Not listed for this material record, condition, or selected unit system.
|
| Thermal conductivity |
Not listed
Not listed for this material record, condition, or selected unit system.
|
| Specific heat capacity |
Not listed
Not listed for this material record, condition, or selected unit system.
|
| Young's modulus |
Not listed
Not listed for this material record, condition, or selected unit system.
|
| Shear modulus |
Not listed
Not listed for this material record, condition, or selected unit system.
|
| Poisson's ratio |
Not listed
Not listed for this material record, condition, or selected unit system.
|
| Yield strength |
117.211 MPa
Tensile yield strength, L
Historical Specified Minimum
Aluminum 3003-H14; plate and sheet; 0.009-1.000 in (0.2286-25.4 mm); longitudinal/parallel-to-working direction; Conservative whole-card aggregation: each retained minimum is the lowest requirement over the stated full thickness range; a maximum is retained only when it applies to every listed sub-band.
|
| Tensile strength |
137.895 MPa
Ultimate tensile strength, L
Historical Specified Minimum
Aluminum 3003-H14; plate and sheet; 0.009-1.000 in (0.2286-25.4 mm); longitudinal/parallel-to-working direction; Conservative whole-card aggregation: each retained minimum is the lowest requirement over the stated full thickness range; a maximum is retained only when it applies to every listed sub-band.
179.264 MPa
Maximum ultimate tensile strength, L
Historical Specified Maximum
Aluminum 3003-H14; plate and sheet; 0.009-1.000 in (0.2286-25.4 mm); longitudinal/parallel-to-working direction; Conservative whole-card aggregation: each retained minimum is the lowest requirement over the stated full thickness range; a maximum is retained only when it applies to every listed sub-band.
|
| Elongation at break |
Not listed
Not listed for this material record, condition, or selected unit system.
|
| Maximum service temperature |
Not listed
Not listed for this material record, condition, or selected unit system.
|