Material picker
0 selected Select up to 5 materials for a readable table.
Comparison

1 materials

Property EN AW-2618A-T61 forging, overaged 1000 h at 230 degC (CC BY experimental)
EN AW-2618A forged cylindrical blank, initially T61, then overaged 1000 h at 230 degC and air cooled | forged cylindrical blank; semi-finished stock for radial compressor wheels
Density
Not listed
Not listed for this material record, condition, or selected unit system.
Thermal conductivity
Not listed
Not listed for this material record, condition, or selected unit system.
Specific heat capacity
Not listed
Not listed for this material record, condition, or selected unit system.
Young's modulus
Not listed
Not listed for this material record, condition, or selected unit system.
Shear modulus
Not listed
Not listed for this material record, condition, or selected unit system.
Poisson's ratio
Not listed
Not listed for this material record, condition, or selected unit system.
Yield strength
265.0 MPa
Tensile yield strength
Reported Ccby Experimental Screening
EN AW-2618A forged blank, T61 plus 1000 h at 230 degC overageing; rectangular blocks 16 x 16 x 100 mm extracted from section 3; one tensile test per temperature; room temperature
181.0 MPa
Tensile yield strength at 230 degC
Reported Ccby Experimental Screening
EN AW-2618A forged blank, T61 plus 1000 h at 230 degC overageing; rectangular blocks 16 x 16 x 100 mm extracted from section 3; one tensile test per temperature; test temperature 230 degC
Tensile strength
351.0 MPa
Ultimate tensile strength
Reported Ccby Experimental Screening
EN AW-2618A forged blank, T61 plus 1000 h at 230 degC overageing; rectangular blocks 16 x 16 x 100 mm extracted from section 3; one tensile test per temperature; room temperature
191.0 MPa
Ultimate tensile strength at 230 degC
Reported Ccby Experimental Screening
EN AW-2618A forged blank, T61 plus 1000 h at 230 degC overageing; rectangular blocks 16 x 16 x 100 mm extracted from section 3; one tensile test per temperature; test temperature 230 degC
Elongation at break
Not listed
Not listed for this material record, condition, or selected unit system.
Maximum service temperature
Not listed
Not listed for this material record, condition, or selected unit system.