Properties
Physical
Property Value Unit
Sample A laminate thickness 2.4 mm
Sample B laminate thickness 1.7 mm
Damage condition
Property Value Unit
Star-punch force 5.0 kN
Sample A damage penetration depth 317.0 um
Sample B damage penetration depth 300.0 um
Sample A visibly damaged area 12.0 mm^2
Sample B visibly damaged area 9.0 mm^2
Processing
Property Value Unit
Nominal system cure temperature 175.0 degC
Test condition
Property Value Unit
Tensile test temperature 20.0 degC
Cyclic tensile test frequency 5.0 Hz
Units
Condition
Condition
autoclaved T300/Code 69 UD-prepreg multidirectional strip laminates with reproducible star-punch surface damage
Temper
not applicable
Heat treatment
Code 69 described as a 175 degC high-pressure, high-bleed system; detailed cure dwell/pressure not supplied
Product form
UD prepreg built into multidirectional Sample A and cross-ply Sample B strip laminates
Thickness / diameter range
2.4 mm total laminate (A) and 1.7 mm total laminate (B); no ply thickness inferred
Test direction
strip longitudinal tensile loading; exact relation to every ply axis depends on stated layup
Processing route
autoclave-prepared T300/Code 69 UD-prepreg laminates
Temperature range
20.0 ... 20.0 degC
Notes
NASA-TM-75351 identifies the exact carbon/epoxy system and documented laminate-strip test configurations, but does not tabulate absolute lamina modulus, strength, strain, thermal expansion, interlaminar shear, density, resin fraction or glass-transition temperature. Its strength and fatigue results are primarily normalized plots. PropLib imports no curve-digitized values, does not infer ply thickness from total laminate thickness, and does not convert the report's qualitative damage-strength discussion into a numerical property. The 175 degC description is a system/process reference, not a fully specified cure cycle or glass-transition temperature.
Standards

No material standards linked.

Record status
Category
Composite
Unit system
Common SI