Properties
Mechanical
Property Value Unit
Ultimate tensile strength, L 99.974 MPa
Tensile yield strength, L 41.369 MPa
Elongation, L 8 %
Units
Condition
Condition
Aluminum 3003-H112, historical QQ-A-250/2E minimums
Temper
H112
Heat treatment
as defined by the historical temper designation
Product form
plate and sheet
Thickness / diameter range
0.250-3.000 in (6.35-76.2 mm)
Test direction
longitudinal / parallel to direction of working
Processing route
rolled
Temperature range
21 ... 21 degC
Notes
Room-temperature historical federal-specification requirements limited to the exact alloy, temper, product form, size range and direction stated by this card. Confirm a current procurement specification and material test report before use.
Standards

No material standards linked.

Record status
Category
Metal
Unit system
Common SI